Warning: mkdir(): No space left on device in /www/wwwroot/zhenghe1718.com/func.php on line 127

Warning: file_put_contents(./cachefile_yuan/pkscc.com/cache/98/84991/357eb.html): failed to open stream: No such file or directory in /www/wwwroot/zhenghe1718.com/func.php on line 115
 Capture MPO-ANCA WIESLAB® (CAP MPOIU) |产品详情|进口橙子视频旧款采购网




  • 橙子视频app安卓下载,91橙子视频,橙子视频旧款,橙子视频在线官网

    订购信息
    上海橙子视频app安卓下载生物科技公司
    Tel:400-968-7988    021-33779008
    Capture MPO-ANCA WIESLAB® (CAP MPOIU)
    品牌:Svar Life Science
    货号:
    规格:
    货期:

    Capture MPO-ANCA WIESLAB® (CAP MPOIU)

    商品详情 参考文献 相关资料

    Capture MPO-ANCA WIESLAB®

    Add to my product list
    Not for sale in the US

    Measurement of MPO-specific ANCA is an important adjunct to clinical findings in the evalsuation of clinical subtypes within the systemic vasculitides spectrum. The Wieslab® Capture MPO-ANCA is calibrated against the AF-CDC international standard (Reference Human Serum 15, code IS2720).

    Product code
    CAP MPOIU
    Format
    ELISA
    Tests
    96 wells
    Calculation
    Quantitative
    Antigen
    Purified MPO antigen (IgG)
    Units
    IU/mL
    Calibrators
    6
    Range
    0-200 IU/mL
    Incubation time
    60+30+30 min
    Detection system
    405 nm
    Availability
    Cap MPO IU: CE marked.
    • Intended use
    • Product Details

    Intended use

    The Wieslab® Capture MPO-ANCA test kit is an enzyme-linked immunosorbent assay (ELISA) for detection and quantitation of IgG antibodies to myeloperoxidase (MPO) in human sera. The results of the assay are to be used as an aid to the diagnosis of microscopic polyangiitis (MP). The assay is intended for use in patients with signs and symptoms consistent with MP. It is not intended for screening a healthy population. The analysis should be performed by trained laboratory professionals.

    FOR IN VITRO DIAGNOSTIC USE.

    Background

    ANCAs (anti-neutrophil cytoplasmic antibodies) are a family of autoantibodies related to vasculitis and inflammatory disorders. When c-ANCA was shown to relate to granulomatosis with polyangiitis (Wegener's granulomatosis (WG)), interest in ANCAs has increased steadily, and today these antibodies are considered to be a major diagnostic tools for the investigation of systemic vasculitis.

    The first method to detect ANCA was indirect immunofluorescence (IIF) performed on ethanol fixed granulocytes. This method yields two patterns, a cytoplasmic staining of the granulocyte denoting the presence of c-ANCAs, and a perinuclear staining denoting the presence of p-ANCAs. IIF was followed by ELISAs using purified proteins.

    The granulocyte is full of granules each with many different proteins. The most important proteins were proteinase 3 (PR3) and myeloperoxidase (MPO). Thus antibodies to proteinase 3 are termed PR3-ANCA, and antibodies to myeloperoxidase are termed MPO-ANCA.

    Approximately 80-90% of WG patients manifest PR3-ANCA and 5-15% MPO-ANCA. One category of vasculitis is microscopic polyangiitis (MP). Most patients with active MP are characterised by positive ANCA test results, MPO-ANCA being more frequent than PR3-ANCA.

    An international workgroup has developed an international standard for MPO-ANCA serology. The Wieslab® Capture MPO-ANCA is calibrated against the AF-CDC international standard (Reference Human Serum 15, code IS2720).

    Technical information

    The wells of the microtitre plate are coated with purified anti-MPO monoclonal antibody and myeloperoxidase. During the first incubation, specific antibodies in diluted serum, will bind to the antigen coating.

    The wells are then washed to remove unbound antibodies and other components.

    A conjugate of alkaline phosphatase-labelled antibodies to human IgG binds to the antibodies in the wells in this second incubation.

    After a further washing step, detection of specific antibodies is obtained by incubation with substrate solution. The amount of bound antibodies correlates to the colour intensity and is measured in terms of absorbance (optical density (OD)). The absorbance is then calculated against a calibrator curve and the results are given in IU/mL.

    • 关于橙子视频app安卓下载
    • 购物流程
    • 支付方式
    • 配送方式
    Copyright@ 2003-2025  进口橙子视频旧款采购网版权所有     

    BIOLEAF热搜   BIOLEAF91橙子视频   BIOLEAF ELISA   BIOLEAF橙子视频旧款   BIOLEAF品牌   BIOLEAF抗体   BIOLEAF耗材   BIOLEAF小仪器

    sitemap   细胞库查询   危险品图标

    本公司网站所展示销售的产品仅供科研!

             沪ICP备08023583号-6     
    产品咨询
    QQ扫码沟通
    在线客服
    服务电话
    400-968-7988
    扫码关注
    微信公众号二维码

    沪公网安备 31011202007338号

    网站地图